Wide Slabs Load Span Tables

  1. The allowable span (mm) for each floor depth may be read from under the applied live load in each case. The allowable span is the maximum permitted distance between support centres. These figures may be increased under certain circumstances of spans and loadings by provision of additional prestressing strands to the slab. Please consult our design department for further information.
  2. Figures tabulated include an allowance for self-weight of the composite floor slab. No allowance is taken for floor finishing screeds, partitions, services, ceilings etc.
  3. The table is not intended as a substitute for design. Further considerations of concentrated loading, openings, notches, camber, deflection, conditions of handling and transportation may limit the permitted spans tabulated. Please contact our design department to discuss all design considerations.
Floor Type Composite Depth(mm) Applied Live Load - Kn/m2
1.50 2.00 2.50 3.00 4.00 5.00 7.50
150/60 150 5300 5100 4950 4750 4550 4300 3900
175/75 175 6600 6400 6200 6000 5700 5500 5000
200/85 200 7700 7600 7450 7300 7150 6850 6100
225/100 225 8250 8000 7900 7800 7500 7350 6700
250/100 250 8800 8650 8500 8400 8100 7800 7200
Quality Assurance IPCA ICMA ICF